Supermicro AS-1115SV-WTNRT SPECpower_ssj2008 = 10,356 overall ssj_ops/watt
Test Sponsor: Supermicro SPEC License #: 1176 Test Method: Single Node
Tested By: Supermicro Test Location: San Jose, CA, USA Test Date: Sep 5, 2023
Hardware Availability: Sep-2023 Software Availability: Apr-2023 Publication: Sep 27, 2023
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 99.4% 2,238,526 133 16,813
90% 90.2% 2,031,197 130 15,621
80% 79.9% 1,799,234 126 14,264
70% 70.0% 1,574,960 122 12,871
60% 60.1% 1,351,833 117 11,547
50% 49.9% 1,122,472 107 10,509
40% 40.1% 901,943 103 8,740
30% 30.2% 679,752 100 6,796
20% 19.9% 448,543 96.3 4,659
10% 10.0% 225,005 91.2 2,467
Active Idle 0 68.5 0
∑ssj_ops / ∑power = 10,356
Graph of results
System Under Test
Set: 'sut'
Set Identifier: sut
Set Description: System Under Test
# of Identical Nodes: 1
Comment: None
Hardware
Hardware Vendor: Supermicro
Model: AS-1115SV-WTNRT
Form Factor: 1U
CPU Name: AMD EPYC 8124PN
CPU Characteristics: 16-Core, 2.0 GHz, 64MB L3 Cache
CPU Frequency (MHz): 2000
CPU(s) Enabled: 16 cores, 1 chip, 16 cores/chip
Hardware Threads: 32 (2 / core)
CPU(s) Orderable: 1 chip
Primary Cache: 512 KB I + 512 KB D on chip per core
Secondary Cache: 16 MB I+D on chip per core
Tertiary Cache: 64 MB I+D on chip per chip
Other Cache: None
Memory Amount (GB): 96
# and size of DIMM: 6 x 16 GB
Memory Details: 6 x 16GB 1Rx8 PC5-4800B; CPU1 A1,B1,C1,D1,E1,F1 populated.
Power Supply Quantity and Rating (W): 1 x 860
Power Supply Details: PWS-861A-1R
Disk Drive: 1 x 1TB Samsung SSD 980 PRO
Disk Controller: Embedded SATA Controller
# and type of Network Interface Cards (NICs) Installed: 1 x Dual LAN BCM 57416 10GbE BaseT Ethernet Controller
NICs Enabled in Firmware / OS / Connected: 2/2/1
Network Speed (Mbit): 10000
Keyboard: None
Mouse: None
Monitor: None
Optical Drives: No
Other Hardware: None
Software
Power Management: Enabled (see SUT Notes)
Operating System (OS): Microsoft Windows Server 2022 Datacenter
OS Version: Version 21H2 (OS Build 20348.1668)
Filesystem: NTFS
JVM Vendor: Oracle Corporation
JVM Version: Java HotSpot(TM) 64-Bit Server VM (build 17.0.1+12-LTS-39, mixed mode, sharing)
JVM Command-line Options: -server -Xms2048m -Xmx2048m -Xmn1900m -XX:+UseParallelGC -XX:ParallelGCThreads=4 -XX:+UseLargePages -XX:LargePageSizeInBytes=2m -XX:+UseBiasedLocking -XX:InlineSmallCode=1500 -XX:UseAVX=1 -XX:AutoBoxCacheMax=20000 -XX:+OptimizeFill -XX:+AggressiveHeap
JVM Affinity: start/NODE[0] /AFFINITY [0xF, 0xF0, 0xF00, 0xF000, 0xF0000, 0xF00000, 0xF000000, 0xF0000000 ]
JVM Instances: 8
JVM Initial Heap (MB): 2048
JVM Maximum Heap (MB): 2048
JVM Address Bits: 64
Boot Firmware Version: 1.0
Management Firmware Version: 01.01.01
Workload Version: SSJ 1.2.10
Director Location: Controller
Other Software: KB5025230
Boot Firmware Settings
Management Firmware Settings
Fan Mode: Standard Speed
System Under Test Notes
Controller System
Hardware
Hardware Vendor: HP
Model: HP EliteBook 745 G6
CPU Description: AMD Ryzen 7 PRO 3700U
Memory amount (GB): 32
Software
Operating System (OS): Microsoft Windows Server 2019 Standard
JVM Vendor: OpenJDK
JVM Version: OpenJDK 64-Bit Server VM 18.9 (build 11.0.2+9, mixed mode)
CCS Version: 1.2.6
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: YOKOGAWA, Inc.
Model: WT310E
Serial Number: C2XM03068V
Connectivity: USB2
Input Connection: Default
Metrology Institute: TESCOM
Accredited by: 12-May-2023
Calibration Label: T114528
Date of Calibration: 12-May-2023
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.10.0-82175bac-20220817
Setup Description: Connected to PSU 1
Temperature Sensor temp1
Hardware Vendor: iButtonLink, Inc.
Model: LinkUSBi + T-Probe
Driver Version: FTDI USB Serial Device 1.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: 50 mm in front of SUT main intake
Notes
None
Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 133 24.0
90% 130 24.1
80% 126 24.1
70% 122 24.1
60% 117 24.1
50% 107 24.1
40% 103 24.1
30% 100 23.9
20% 96.3 23.9
10% 91.2 23.9
Active Idle 68.5 23.9
Line Standard Minimum Temperature (°C) Elevation (m)
220V / 60 Hz / 1 phase / 2 wires 23.9 132
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     2,294,809
Calibration 2     2,253,347
Calibration 3     2,248,692
ssj_ops@calibrated=2,251,020
100% 99.4% 2,251,020 2,238,526
90% 90.2% 2,025,918 2,031,197
80% 79.9% 1,800,816 1,799,234
70% 70.0% 1,575,714 1,574,960
60% 60.1% 1,350,612 1,351,833
50% 49.9% 1,125,510 1,122,472
40% 40.1% 900,408 901,943
30% 30.2% 675,306 679,752
20% 19.9% 450,204 448,543
10% 10.0% 225,102 225,005
Active Idle   0 0
Graph of results