SPECpower_ssj2008 Copyright (C) 2007-2018 Standard Performance Evaluation Corporation Fujitsu FUJITSU Server PRIMERGY TX1320 M4 SPECpower_ssj2008 = 9,435 overall ssj_ops/watt Test Sponsor: Fujitsu SPEC License #: 19 Tested By: Fujitsu Test Location: Kawasaki, Kanagawa, Japan Test Date: Nov 22, 2018 Publication: Dec 6, 2018 Hardware Availability: Nov-2018 Software Availability: Sep-2018 Test Method: Single Node System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered Benchmark Results Summary Performance | Power | Performance | | to Power | | Ratio Target Load | Actual Load | ssj_ops | Average | | | | Active Power | | | | (W) | ------------- | ------------- | ------------- | ------------- | ------------- 100% | 100.3% | 655,699 | 71.7 | 9,148 90% | 90.2% | 589,566 | 60.6 | 9,723 80% | 79.9% | 522,263 | 50.0 | 10,440 70% | 69.8% | 455,895 | 41.9 | 10,890 60% | 60.0% | 391,846 | 35.5 | 11,050 50% | 49.8% | 325,677 | 30.0 | 10,863 40% | 39.8% | 260,292 | 25.5 | 10,211 30% | 30.1% | 196,623 | 21.8 | 9,023 20% | 20.0% | 130,916 | 18.4 | 7,096 10% | 9.9% | 65,014 | 15.5 | 4,192 Active Idle | 0 | 10.0 | 0 sum of ssj_ops / sum of power = | 9,435 System Under Test Set: 'TX1320 M4' Set Identifier: TX1320 M4 Set Description: System Under Test # of Identical Nodes: 1 Comment: Single Node HARDWARE Hardware Vendor: Fujitsu Model: FUJITSU Server PRIMERGY TX1320 M4 Form Factor: Tower CPU Name: Intel Xeon E-2176G CPU Characteristics: 6-Core, 3.7GHz, 12MB L3 Cache CPU Frequency (MHz): 3700 CPU(s) Enabled: 6 cores, 1 chip, 6 cores/chip Hardware Threads: 12 (2 / core) CPU(s) Orderable: 1 chip Primary Cache: 32 KB I + 32 KB D on chip per core Secondary Cache: 256 KB I+D on chip per core Tertiary Cache: 12 MB I+D on chip per chip Other Cache: None Memory Amount (GB): 16 # and size of DIMM: 2 x 8192 MB Memory Details: 8 GB DDR4, unbuffered, ECC, 2666 MHz, DIMM, 1Rx8; slots 1A, 1B, populated Power Supply Quantity and Rating 1 x 250 (W): Power Supply Details: Standard power supply part of base unit S26361-K1638-V201 Disk Drive: 1 x M.2 SSD 240GB, S26361-F5706-E240 Disk Controller: Integrated SATA Controller # and type of Network Interface 2 x Intel I210 Gigabit Network Connection Cards (NICs) Installed: (onboard) NICs Enabled in Firmware / OS / 1/1/1 Connected: Network Speed (Mbit): 1000 Keyboard: None Mouse: None Monitor: None Optical Drives: No Other Hardware: None SOFTWARE Power Management: Enabled ("Power saver" power plan in OS) Operating System (OS): Microsoft Windows Server 2012 R2 Standard OS Version: Version 6.3.9600 Build 9600 Filesystem: NTFS JVM Vendor: Oracle Corporation JVM Version: Oracle Java HotSpot(TM) 64-Bit Server VM 18.9(build 11+28, mixed mode), version 11 JVM Command-line Options: -server -Xmn10500m -Xms12000m -Xmx12000m -XX:SurvivorRatio=1 -XX:TargetSurvivorRatio=99 -XX:AllocatePrefetchDistance=256 -XX:AllocatePrefetchLines=4 -XX:ParallelGCThreads=2 -XX:InlineSmallCode=3900 -XX:MaxInlineSize=270 -XX:FreqInlineSize=2500 -XX:+UseLargePages -XX:+UseParallelOldGC -XX:AllocatePrefetchInstr=0 -XX:MinJumpTableSize=18 -XX:UseAVX=0 -XX:TenuredGenerationSizeSupplement=40 -XX:-UseFastStosb JVM Affinity: none JVM Instances: 1 JVM Initial Heap (MB): 12000 JVM Maximum Heap (MB): 12000 JVM Address Bits: 64 Boot Firmware Version: R1.1.0 Management Firmware Version: 1.60h Workload Version: SSJ 1.2.10 Director Location: Controller Other Software: Microsoft Windows KB4054519 Boot Firmware Settings * Set "ASPM Support = Force F0s" in BIOS. * Set "Adjacent Cache Line Prefetch = Disabled" in BIOS. * Set "Hardware Prefecher = Disable" in BIOS. * Set "DCU Streamer Prefetcher = Disable" in BIOS. * Set "Intel Virtualization Technology = Disable" in BIOS. * Set "SATA Port 1/2/3/4/5/7 = Disable" in BIOS. * Set "Turbo = Disabled" in BIOS. * Set "Serial port = Disabled" in BIOS. * Set "LAN2 = Disabled" in BIOS. * Set "USB Port Control = Enable internal ports only" in BIOS. * Set "Software Guard Extensions = Disabled" in BIOS. * Set "Network Stack = Disabled" in BIOS. Management Firmware Settings None System Under Test Notes * Set "Turn off hard disk after = 1 Minute" in OS. * Set "Turn off display after = 1 Minute" in OS. * Set "Minimum processor state = 0%" in OS. * Set "Maximum processor state = 100%" in OS. * Using the local security settings console, "lock pages in memory" was enabled for the user running the benchmark. * Benchmark was started via Windows Remote Desktop Connection. * SPECpower_ssj.props input.load_level.number_warehouses set to 12. * <Yes>: The test sponsor attests, as of date of publication, that CVE-2017-5754 (Meltdown) is mitigated in the system as tested and documented. * <Yes>: The test sponsor attests, as of date of publication, that CVE-2017-5753 (Spectre variant 1) is mitigated in the system as tested and documented. * <Yes>: The test sponsor attests, as of date of publication, that CVE-2017-5715 (Spectre variant 2) is mitigated in the system as tested and documented. Controller System HARDWARE Hardware Vendor: Fujitsu Model: PRIMERGY RX2530 M2 CPU Description: 2x Intel Xeon E5-2643 v4 Memory amount (GB): 64 SOFTWARE Operating System (OS): Microsoft Windows Server 2012 R2 Standard JVM Vendor: Oracle Corporation JVM Version: Oracle Java HotSpot(TM) 64-Bit Server VM 18.9(build 11+28, mixed mode) CCS Version: 1.2.6 Measurement Devices POWER ANALYZER PWR1 Hardware Vendor: Hioki Model: Hioki3336 Serial Number: 170121768 Connectivity: RS-232 Input Connection: Default Metrology Institute: NICT (National Institute of Information and Communications Technology) Accredited by: HIOKI E.E. CORPORATION Calibration Label: H06400086-1801 Date of Calibration: 31-Jan-2018 PTDaemon Host System: same as CCS PTDaemon Host OS: same as CCS PTDaemon Version: 1.8.1-260d064e-20161220 Setup Description: Connected to PSU 1 TEMPERATURE SENSOR TEMP1 Hardware Vendor: Digi International Inc. Model: Watchport/H Driver Version: Watchport Virtual Port 5.10.26.0 Connectivity: USB PTDaemon Host System: same as CCS PTDaemon Host OS: same as CCS Setup Description: 5 mm in front of SUT main air intake Notes * None Aggregate Electrical and Environmental Data Target Load | Average | Minimum | Active | Ambient | Power (W) | Temperature | | (Degrees C) ----------- | ---------- | ------------- 100% | 71.7 | 25.2 90% | 60.6 | 25.0 80% | 50.0 | 24.9 70% | 41.9 | 24.9 60% | 35.5 | 24.8 50% | 30.0 | 24.9 40% | 25.5 | 24.9 30% | 21.8 | 24.8 20% | 18.4 | 24.8 10% | 15.5 | 24.8 Active Idle | 10.0 | 24.8 Line Standard | Minimum | Elevation (m) | Temperature | | (Degrees C) | ------------------------- | --------------- | --------------- 200V / 50 Hz / 1 phase / | 24.8 | 11 2 wires | | See the Power/Temperature Details Report (power_ssj2008-20181125-00869-power.txt) for additional details. Aggregate Performance Data Target Load | Actual Load | ssj_ops | | Target | Actual ----------------- | ----------------- | ----------------- | ----------------- Calibration 1 | | | 654,458 Calibration 2 | | | 654,245 Calibration 3 | | | 652,634 ssj_ops@calibrated=653,440 100% | 100.3% | 653,440 | 655,699 90% | 90.2% | 588,096 | 589,566 80% | 79.9% | 522,752 | 522,263 70% | 69.8% | 457,408 | 455,895 60% | 60.0% | 392,064 | 391,846 50% | 49.8% | 326,720 | 325,677 40% | 39.8% | 261,376 | 260,292 30% | 30.1% | 196,032 | 196,623 20% | 20.0% | 130,688 | 130,916 10% | 9.9% | 65,344 | 65,014 Active Idle | | 0 | 0 See the JVM Instance Performance Report (power_ssj2008-20181125-00869-ad-100.001.txt) for additional details. Copyright (C) 2007-2018 Standard Performance Evaluation Corporation http://www.spec.org - info@spec.org SPECpower_ssj2008 Reporter Version: [SSJ 1.2.10, May 9, 2012]