Acer Incorporated Altos T350 F2 SPECpower_ssj2008 = 5,091 overall ssj_ops/watt
Test Sponsor: Acer Incorporated SPEC License #: 97 Test Method: Single Node
Tested By: Acer Incorporated Test Location: Taipei, R.O.C. Test Date: Jun 6, 2013
Hardware Availability: May-2013 Software Availability: Jun-2012 Publication: Jul 16, 2013
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 99.9% 1,460,890 255 5,728
90% 90.1% 1,317,554 226 5,834
80% 80.0% 1,170,299 197 5,946
70% 69.9% 1,022,619 168 6,071
60% 60.1% 879,641 145 6,062
50% 50.2% 733,828 126 5,827
40% 40.0% 585,743 114 5,150
30% 30.0% 438,261 104 4,203
20% 19.9% 290,987 93.8 3,103
10% 10.0% 146,682 83.1 1,766
Active Idle 0 68.5 0
∑ssj_ops / ∑power = 5,091
Graph of results
System Under Test
Set: 'sut'
Set Identifier: sut
Set Description: System Under Test
# of Identical Nodes: 1
Comment: None
Hardware
Hardware Vendor: Acer Incorporated
Model: Altos T350 F2
Form Factor: 2U
CPU Name: Intel Xeon E5-2660 2.2 GHz (Intel Turbo Boost Technology up to 3.00 GHz)
CPU Characteristics: 8 core, 2.20 GHz, 20MB L3 Cache
CPU Frequency (MHz): 2200
CPU(s) Enabled: 16 cores, 2 chips, 8 cores/chip
Hardware Threads: 32 (2 / core)
CPU(s) Orderable: 1,2 chips
Primary Cache: 32 KB I + 32 KB D on chip per core
Secondary Cache: 256 KB I+D on chip per core
Tertiary Cache: 20 MB I+D on chip per chip
Other Cache: None
Memory Amount (GB): 24
# and size of DIMM: 6 x 4096 MB
Memory Details: 4GB 2Rx8 PC3L-10600E; slots A1, B1, C1, E1, F1 and G1 populated
Power Supply Quantity and Rating (W): 1 x 750
Power Supply Details: Acer P/N SC.75017.002
Disk Drive: 1 x 240GB SSD 2.5" SATA, Acer P/N KN.2400N.002
Disk Controller: onboard SCU controller
# and type of Network Interface Cards (NICs) Installed: 1 x Quad-port Intel I350 Gigabit Ethernet controller
NICs Enabled in Firmware / OS / Connected: 1/1/1
Network Speed (Mbit): 1000
Keyboard: None
Mouse: None
Monitor: None
Optical Drives: No
Other Hardware: None
Software
Power Management: Power Saver Mode enabled in OS
Operating System (OS): Windows Server 2008, Enterprise Edition
OS Version: R2 SP1
Filesystem: NTFS
JVM Vendor: IBM Corporation
JVM Version: IBM J9 VM (build 2.6, JRE 1.7.0 Windows Server 2008 R2 amd64-64 20120322_106209 JIT enabled, AOT enabled)
JVM Command-line Options: -Xaggressive -Xcompressedrefs -Xmx1600m -Xms1600m -Xmn1200m -XlockReservation - Xnoloa -XtlhPrefetch -Xlp -Xconcurrentlevel0
JVM Affinity: start /affinity [0F,F0,F00,F000,F0000,F00000,F000000,F0000000]
JVM Instances: 8
JVM Initial Heap (MB): 1600
JVM Maximum Heap (MB): 1600
JVM Address Bits: 64
Boot Firmware Version: 01.06.0002
Management Firmware Version: 1.17.4151
Workload Version: SSJ 1.2.10
Director Location: Controller
Other Software: IBM SDK Java Technology Edition Version 7.0 for Windows x64
Boot Firmware Settings
Management Firmware Settings
None
System Under Test Notes
Controller System
Hardware
Hardware Vendor: Acer Incorporated
Model: Acer AR160 F1
CPU Description: Xeon L5520
Memory amount (GB): 3
Software
Operating System (OS): Windows Server 2003 R2, Enterprise Edition SP2
JVM Vendor: Oracle Corporation
JVM Version: Oracle JRockit(R) (build R27.5.0-110_o-99226-1.6.0_03-20080528-1505-windows-ia32, compiled mode)
CCS Version: 1.2.6
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Yokogawa Electric International Pte. Ltd.
Model: WT210
Serial Number: 91H534921
Connectivity: RS232
Input Connection: Default
Metrology Institute: NML (National Measurement Laboratory, R.O.C.)
Accredited by: ETC, Taiwan
Calibration Label: 13-04-BAC-380-01
Date of Calibration: 9-May-2013
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.6.0-7f9b1b00-20130314
Setup Description: None
Temperature Sensor temp1
Hardware Vendor: Digi International Inc.
Model: Watchport/H
Driver Version: Watchport Virtual Port 5.0.0.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: 5 mm in front of SUT airflow intake
Notes
None
Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 255 22.9
90% 226 22.8
80% 197 22.8
70% 168 22.8
60% 145 22.7
50% 126 22.7
40% 114 22.7
30% 104 22.7
20% 93.8 22.6
10% 83.1 22.6
Active Idle 68.5 22.6
Line Standard Minimum Temperature (°C) Elevation (m)
220V / 60 Hz / 1 phase / 2 wires 22.6 132
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     1,412,336
Calibration 2     1,462,623
Calibration 3     1,463,502
ssj_ops@calibrated=1,463,063
100% 99.9% 1,463,063 1,460,890
90% 90.1% 1,316,756 1,317,554
80% 80.0% 1,170,450 1,170,299
70% 69.9% 1,024,144 1,022,619
60% 60.1% 877,838 879,641
50% 50.2% 731,531 733,828
40% 40.0% 585,225 585,743
30% 30.0% 438,919 438,261
20% 19.9% 292,613 290,987
10% 10.0% 146,306 146,682
Active Idle   0 0
Graph of results