IBM Corporation IBM System x3300 M4 SPECpower_ssj2008 = 5,122 overall ssj_ops/watt
Test Sponsor: IBM Corporation SPEC License #: 11 Test Method: Single Node
Tested By: IBM Corporation Test Location: Taipei, Taiwan Test Date: Aug 3, 2012
Hardware Availability: Sep-2012 Software Availability: Jun-2012 Publication: Aug 22, 2012
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 99.8% 1,460,149 259 5,632
90% 90.0% 1,316,466 237 5,564
80% 79.8% 1,167,165 189 6,177
70% 70.2% 1,027,412 176 5,846
60% 60.0% 877,348 157 5,588
50% 50.1% 733,547 134 5,470
40% 39.7% 580,918 112 5,185
30% 29.9% 437,745 95.9 4,566
20% 20.0% 292,559 84.0 3,483
10% 9.9% 145,371 73.9 1,967
Active Idle 0 52.1 0
∑ssj_ops / ∑power = 5,122
Graph of results
System Under Test
Set: 'sut'
Set Identifier: sut
Set Description: System Under Test
# of Identical Nodes: 1
Comment: None
Hardware
Hardware Vendor: IBM Corporation
Model: IBM System x3300 M4
Form Factor: 4U
CPU Name: Intel Xeon E5-2470
CPU Characteristics: 8-Core, 2.30 GHz, 20MB L3 Cache (Turbo Boost Technology up to 3.10 GHz)
CPU Frequency (MHz): 2300
CPU(s) Enabled: 16 cores, 2 chips, 8 cores/chip
Hardware Threads: 32 (2 / core)
CPU(s) Orderable: 1, 2 chips
Primary Cache: 32 KB I + 32 KB D on chip per core
Secondary Cache: 256 KB I+D on chip per chip
Tertiary Cache: 20 MB I+D on chip per chip
Other Cache: None
Memory Amount (GB): 24
# and size of DIMM: 6 x 4096 MB
Memory Details: 4GB 2Rx8 PC3L-10600E; slots 1, 3, 5, 7, 9 and 11 populated
Power Supply Quantity and Rating (W): 1 x 550
Power Supply Details: IBM 550w PSU(94Y6668)
Disk Drive: 1 x 256GB SSD(IBM Feature Code: A2U3)
Disk Controller: Integrated SATA controller
# and type of Network Interface Cards (NICs) Installed: 4 x Integrated Intel I350 Gigabit NIC
NICs Enabled in Firmware / OS / Connected: 4/4/1
Network Speed (Mbit): 1000
Keyboard: None
Mouse: None
Monitor: None
Optical Drives: No
Other Hardware: None
Software
Power Management: Enabled (See SUT Note)
Operating System (OS): Microsoft Windows Server 2008 Enterprise Edition x64
OS Version: R2 SP1
Filesystem: NTFS
JVM Vendor: IBM Corporation
JVM Version: IBM J9 VM (build 2.6, JRE 1.7.0 Windows Server 2008 R2 amd64-64 20120322_106209 (JIT enabled, AOT enabled)
JVM Command-line Options: -Xaggressive -Xcompressedrefs -Xmn1100m -Xms1500m -Xmx1500m -XlockReservation -Xnoloa -XtlhPrefetch -Xlp -Xconcurrentlevel0
JVM Affinity: start /affinity [F, F0, F00, F000, F0000, F00000,F000000,F0000000]
JVM Instances: 8
JVM Initial Heap (MB): 1500
JVM Maximum Heap (MB): 1500
JVM Address Bits: 64
Boot Firmware Version: 115D
Management Firmware Version: 31K
Workload Version: SSJ 1.2.9
Director Location: Controller
Other Software: IBM SDK Java Technology Edition Version 7.0 for Windows x64
Boot Firmware Settings
Management Firmware Settings
None
System Under Test Notes
Controller System
Hardware
Hardware Vendor: IBM Corporation
Model: x3650 M3
CPU Description: Intel Xeon L5506
Memory amount (GB): 24
Software
Operating System (OS): Windows 2008 R2 SP1
JVM Vendor: IBM
JVM Version: IBM J9 VM (build 2.4, J2RE 1.6.0 IBM J9 2.4 Windows Server 2008 amd64-64 jvmwa64 60sr5-20090519_35743 (JIT enabled, AOT enabled)
CCS Version: 1.2.5
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Yokogawa Electric International Pte. Ltd.
Model: WT210
Serial Number: 91H245649
Connectivity: RS-232
Input Connection: Default
Metrology Institute: NML/ROC
Accredited by: ETC, Taiwan
Calibration Label: 12-04-BAC-479-01
Date of Calibration: 12-Apr-2012
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.4.1-1271fb18-20110728
Setup Description: none
Temperature Sensor temp1
Hardware Vendor: Digi International, Inc.
Model: Watchport/H
Driver Version: 4.20.0.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: 1 cm in front of SUT main intake
Notes
None
Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 259 20.9
90% 237 21.4
80% 189 21.5
70% 176 21.8
60% 157 21.5
50% 134 21.4
40% 112 21.5
30% 95.9 21.8
20% 84.0 21.6
10% 73.9 21.5
Active Idle 52.1 21.6
Line Standard Minimum Temperature (°C) Elevation (m)
208V / 60 Hz / 1 phase / 2 wires 20.9 63
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     1,432,938
Calibration 2     1,463,201
Calibration 3     1,463,361
ssj_ops@calibrated=1,463,281
100% 99.8% 1,463,281 1,460,149
90% 90.0% 1,316,953 1,316,466
80% 79.8% 1,170,624 1,167,165
70% 70.2% 1,024,296 1,027,412
60% 60.0% 877,968 877,348
50% 50.1% 731,640 733,547
40% 39.7% 585,312 580,918
30% 29.9% 438,984 437,745
20% 20.0% 292,656 292,559
10% 9.9% 146,328 145,371
Active Idle   0 0