-------------------------------------------------------------------------------- SPECjAppServer(R)2004 Result Copyright (C) 2004 Standard Performance Evaluation Corporation -------------------------------------------------------------------------------- Sun Java System Application Server 9.1 on Sun SPARC Enterprise T5120 Cluster -------------------------------------------------------------------------------- 8,439.36 SPECjAppServer2004 JOPS@Standard -------------------------------------------------------------------------------- Submitter: Sun Microsystems Inc. SPEC license # 6 Test date: Oct-2007 -------------------------------------------------------------------------------- SUT CONFIGURATION -------------------------------------------------------------------------------- J2EE Server Nodes: 6 DB Server Nodes: 1 J2EE Server CPUs: 48 cores, 6 chips DB Server CPUs: 48 cores, 24 chips J2EE Instances: 18 DB Instances: 1 Other SUT Components: None -------------------------------------------------------------------------------- BENCHMARK SETTINGS -------------------------------------------------------------------------------- Dealer Injection Rate: 5,100 Ramp Up Time: 600 sec # of Dealer Agents: 100 Ramp Down Time: 300 sec # of Manufacturing Agents: 60 Steady State Time: 3,600 sec DB Load Injection Rate: 6,000 Trigger Time: 2,050 sec -------------------------------------------------------------------------------- Detailed Results -------------------------------------------------------------------------------- Dealer Transaction Mix Count Tx. Mix Purchase 4,569,247 25.00% Manage 4,568,212 25.00% Browse 9,137,447 50.00% Total # Dealer Transactions 18,274,906 Total # Manufacturing Transactions 12,106,803 Response Times Average Maximum 90th% Reqd Purchase 0.56 27.30 1.10 2.00 Manage 0.41 30.18 0.90 2.00 Browse 0.70 23.90 1.50 2.00 Manufacturing 1.83 19.86 3.25 5.00 Reproducibility Run (SPECjAppServer2004 JOPS) 8,442.05 -------------------------------------------------------------------------------- SOFTWARE PRODUCTS -------------------------------------------------------------------------------- Sun Java System Application Server 9.1, Platform Edition Update Release 1 Vendor: Sun Microsystems, Inc. Availability Date: Dec-2007 Date Passed CTS: Feb-2007 CTS Version: JEE5 EJB Protocol: RMI/IIOP OS Name: Solaris 10 8/07 (64-bit) -------------------------------------------------------------------------------- Jakarta Tomcat 5.5.23 Vendor: Apache Software Foundation Availability Date: Sep-2006 -------------------------------------------------------------------------------- Java (TM) 2 Platform Standard Edition Development Kit 6.0 Update 4 32-bit Vendor: Sun Microsystems, Inc. Availability Date: Nov-2007 OS Name: Solaris 10 8/07 (64-bit) -------------------------------------------------------------------------------- Java (TM) 2 Platform Standard Edition Development Kit 6.0 Update 4 64-bit Vendor: Sun Microsystems, Inc. Availability Date: Nov-2007 OS Name: Solaris 10 6/06 (64-bit) -------------------------------------------------------------------------------- DataDirect Connect for JDBC 3.6 Vendor: Sun OEM Version Availability Date: Sep-2007 OS Name: Solaris 10 8/07 (64-bit) -------------------------------------------------------------------------------- IBM DB2 9.1 Vendor: IBM Corporation Availability Date: Feb-2007 OS Name: Solaris 10 8/07 (64-bit) -------------------------------------------------------------------------------- SOFTWARE CONFIGURATIONS -------------------------------------------------------------------------------- J2EE Application Servers J2EE Product: Sun Java System Application Server 9.1, Platform Edition Update Release 1 JVM Product: Java (TM) 2 Platform Standard Edition Development Kit 6.0 Update 4 32-bit JDBC Product: DataDirect Connect for JDBC 3.6 Hardware: J2EE AppServer HW # of Instances: 18 Interfaces: Web Interface for the Dealer Domain Web Interface for the Supplier Domain EJB Interface for the Dealer Domain EJB Interface for the Manufacturing Domain EJB Interface for the Supplier Domain Notes / Tuning Information Tunings in domain.xml: JVM Options: -server -XX:+AggressiveHeap -Xmx2560m -Xms2560m -Xmn1024m -Xss128k -XX:PermSize=256m -XX:+DisableExplicitGC -XX:ParallelGCThreads=24 -XX:LargePageSizeInBytes=256m -XX:+UseParallelOldGC -XX:+AggressiveOpts -DAllowManagedFieldsInDefaultFetchGroup=true -DAllowMediatedWriteInDefaultFetchGroup=true -XX:-UseBiasedLocking -Dcom.sun.ejb.containers.readonly.relative.refresh.mode=true -Dcom.sun.jts.dblogging.insertquery=insert into txn_log_table_0 values ( ? , ? , ? ) -Dcom.sun.jts.dblogging.deletequery=delete from txn_log_table_0 where localtid = ? and servername = ? -Dcom.sun.jdo.spi.persistence.support.sqlstore.MULTILEVEL_PREFETCH=true General Tunings: All application servers run in FX class via priocntl command -------------------------------------------------------------------------------- Emulator SW Config J2EE Product: Jakarta Tomcat 5.5.23 JVM Product: Java (TM) 2 Platform Standard Edition Development Kit 6.0 Update 4 64-bit Hardware: Emulator HW # of Instances: 1 Notes / Tuning Information JVM Options: -d64 -server -Xms20g -Xmx20g -Xmn2g -Xss256k -XX:+UseConcMarkSweepGC -XX:LargePageSizeInBytes=4m -verbose:gc -XX:+PrintGCDetails -XX:+PrintGCTimeStamps -XX:-TraceClassUnloading -XX:PermSize=96m -Dsun.net.inetaddr.ttl=0 -Dnetworkaddress.cache.ttl=0 Tomcat Options: maxThreads=6000 acceptCount=10000 connectionTimeout=20000 -------------------------------------------------------------------------------- Database SW Config DB Product: IBM DB2 9.1 Hardware: Database Server HW # of Instances: 1 Notes / Tuning Information Tuning performed by db2tune.sh script in the archive/Schema directory. DB2 processes run in FX class using priocntl DB2 processes bound across all cores using /usr/sbin/pbind -------------------------------------------------------------------------------- Driver SW Config - Primary and Satellites JVM Product: Java (TM) 2 Platform Standard Edition Development Kit 6.0 Update 4 32-bit Hardware: Load Driver HW - Primary and Satellites # of Instances: 20 Notes / Tuning Information JVM Options: -server -Xmx1600m -Xmx1600m -XX:+DisableExplicitGC -Xss128k -Djava.naming.factory.initial=com.sun.appserv.naming.S1ASCtxFactory -Djava.naming.provider.url=iiop://ecapps:3700 -Djava.naming.provider.url.pkgs=com.sun.enterprise.naming -Dcom.sun.appserv.iiop.endpoints=ecapps:3700 -Dorg.omg.CORBA.ORBInitialHost=ecapps -Dorg.omg.CORBA.ORBInitialPort=3700 -Dsun.net.inetaddr.ttl=0 -Dnetworkaddress.cache.ttl=0 -------------------------------------------------------------------------------- HARDWARE SYSTEMS -------------------------------------------------------------------------------- J2EE AppServer HW (SUT hardware) Hardware Vendor: Sun Microsystems, Inc. Model Name: Sun SPARC Enterprise T5120 Processor: Sun UltraSPARC T2 MHz: 1417 # of CPUs: 8 cores, 1 chip, 8 cores/chip (8 threads/core) Memory (MB): 32768 L1 Cache: 16KB(I)+8KB(D) per core L2 Cache: 4MB per chip Other Cache: OS Vendor: Sun Microsystems, Inc. OS Name: Solaris 10 8/07 (64-bit) Disks: 3x73Gb 10K RPM SAS Network Interface: (4) Onboard Gbit Ethernet and (1) Dual-Port GbE Card Other Hardware: # of Systems: 6 H/W Available: Nov-2007 O/S Available: Sep-2007 Notes / Tuning Information System Tuning in /etc/system: set ip:ip_soft_rings_cnt = 8 Network Tuning: ndd -set /dev/tcp tcp_conn_req_max_q 16384 ndd -set /dev/tcp tcp_conn_req_max_q0 16384 ndd -set /dev/tcp tcp_xmit_hiwat 131072 ndd -set /dev/tcp tcp_recv_hiwat 131072 ndd -set /dev/tcp tcp_naglim_def 1 ndd -set /dev/tcp tcp_smallest_anon_port 4096 The three application server instances were hosted in 3 separate Solaris Containers. Each Container on the systems was connected to 2 subnets. One was a subnet to the switch used for the network traffic between the drivers and the SUT. The first container used e1000g0, the second comtainer used e1000g1 and third container used e1000g2 on each system to connect to the switch. The second subnet in each container was used for database access. The first and second containers shared e1000g3 for this subnet. The third container used e1000g4 for for this subnet. There were a total of 12 network connections from the 6 appservers to the database system. -------------------------------------------------------------------------------- Database Server HW (SUT hardware) Hardware Vendor: Sun Microsystems, Inc. Model Name: Sun Fire E6900 Processor: UltraSPARC IV+ MHz: 1950 # of CPUs: 48 cores, 24 chips, 2 cores/chip Memory (MB): 98304 L1 Cache: 64KB(I)+64KB(D) per core on chip L2 Cache: 2MB(I+D) per core on chip Other Cache: 32MB(I+D) per chip OS Vendor: Sun Microsystems, Inc. OS Name: Solaris 10 8/07 (64-bit) Disks: 1x D240 Media Tray (3x 73Gb 10K RPM Ultra320 SCSI) Network Interface: (12) Sun 1000BaseT Ethernet Other Hardware: 1x Sun STK 3510 Array (12x 73GB FC Disk Array) & 3x Sun STK 3510 Array (12x 146GB FC Disk Array) # of Systems: 1 H/W Available: Apr-2007 O/S Available: Sep-2007 Notes / Tuning Information System Tuning in /etc/system: set ce:ce_bcopy_thresh=513 set ce:ce_dvma_thresh=512 set ce:ce_taskq_disable=1 set ce:ce_ring_size=256 set ce:ce_comp_ring_size=1024 set ce:ce_tx_ring_size=4096 set kernel_cage_enable=0 Network Tuning: ndd -set /dev/tcp tcp_conn_req_max_q 16384 ndd -set /dev/tcp tcp_conn_req_max_q0 16384 ndd -set /dev/tcp tcp_xmit_hiwat 131072 ndd -set /dev/tcp tcp_recv_hiwat 131072 ndd -set /dev/tcp tcp_naglim_def 1 ndd -set /dev/tcp tcp_smallest_anon_port 4096 CE network driver tuning: ndd -set /dev/ce rx_intr_time 32 ndd -set /dev/ce rx_intr_pkts 16 Other Tuning: UFS mount options for database files: noatime,forcedirectio Shared memory settings in /etc/project: user.db2inst1:100:DB2 instance::: project.max-msg-ids=(privileged,12288,deny); project.max-sem-ids=(privileged,14336,deny); project.max-shm-ids=(privileged,14336,deny); project.max-shm-memory=(privileged,96636764160,deny) -------------------------------------------------------------------------------- Emulator HW (non-SUT hardware) Hardware Vendor: Sun Microsystems, Inc. Model Name: Sun Fire V890 Processor: UltraSPARC IV+ MHz: 1800 # of CPUs: 16 cores, 8 chips, 2 cores/chip Memory (MB): 65536 L1 Cache: 64KB(I)+64KB(D) per core on chip L2 Cache: 2MB(I+D) per core on chip Other Cache: 32MB(I+D) per chip OS Vendor: Sun Microsystems, Inc. OS Name: Solaris 10 6/06(64-bit) Disks: 12 x 36Gb FC Network Interface: (2) Onboard 1000BaseT Ethernet Other Hardware: # of Systems: 1 H/W Available: Aug-2006 O/S Available: Jun-2006 Notes / Tuning Information System Tuning in /etc/system: set ce:ce_bcopy_thresh=513 set ce:ce_dvma_thresh=512 set ce:ce_taskq_disable=1 set ce:ce_ring_size=256 set ce:ce_comp_ring_size=1024 set ce:ce_tx_ring_size=4096 Network Tuning: ndd -set /dev/tcp tcp_conn_req_max_q 16384 ndd -set /dev/tcp tcp_conn_req_max_q0 16384 ndd -set /dev/tcp tcp_xmit_hiwat 131072 ndd -set /dev/tcp tcp_recv_hiwat 131072 ndd -set /dev/tcp tcp_naglim_def 1 ndd -set /dev/tcp tcp_smallest_anon_port 4096 CE network driver tuning: ndd -set /dev/ce rx_intr_time 32 ndd -set /dev/ce rx_intr_pkts 16 Only 1 NIC was used for the network traffic between the emulator and the SUT. -------------------------------------------------------------------------------- Load Driver HW - Primary and Satellites (non-SUT hardware) Hardware Vendor: Sun Microsystems, Inc. Model Name: Sun Blade X8420 Server Module Processor: AMD Opteron 8220 MHz: 2800 # of CPUs: 8 cores, 4 chips, 2 cores/chip (4 chips/blade) Memory (MB): 32768 L1 Cache: 64KB(I)+64KB(D) per core L2 Cache: 2MB per chip Other Cache: OS Vendor: Sun Microsystems, Inc. OS Name: Solaris 10 11/06 (64-bit) Disks: 2x73Gb 10K RPM SAS Network Interface: (4) Onboard 1000BaseT Ethernet Other Hardware: # of Systems: 10 H/W Available: Jan-2007 O/S Available: Nov-2006 Notes / Tuning Information Network Tuning: ndd -set /dev/tcp tcp_conn_req_max_q 16384 ndd -set /dev/tcp tcp_conn_req_max_q0 16384 ndd -set /dev/tcp tcp_xmit_hiwat 131072 ndd -set /dev/tcp tcp_recv_hiwat 131072 ndd -set /dev/tcp tcp_naglim_def 1 ndd -set /dev/tcp tcp_smallest_anon_port 4096 Each blade was divided into 2 logical partitions using Solaris Containers. 2 satellite drivers ran in separate containers on each blade. Each container used a separate network interface to access the SUT. -------------------------------------------------------------------------------- BENCHMARK MODIFICATIONS -------------------------------------------------------------------------------- Schema Modifications: Tablespace sizes were increased to support the Injection rate. Scripts to create the DB are included in the FDA. -------------------------------------------------------------------------------- Load Program Modifications: The load program was not modified BENCHMARK CONFIGURATION INFORMATION -------------------------------------------------------------------------------- Isolation Requirement Info: BEAN SPEC_REQUIREMENT Deployment Corp.CustomerEnt Repeatable Read RS Corp.CustomerInventoryEnt Repeatable Read RS Mfg.InventoryEnt Repeatable Read RS Mfg.WorkOrderEnt Repeatable Read RS Orders.OrderEnt Repeatable Read RS Orders.OrderLineEnt Repeatable Read RS Supplier.POEnt Repeatable Read RS Supplier.POLineEnt Repeatable Read RS Supplier.SComponentEnt Repeatable Read RS Util.SequenceEnt Repeatable Read RS Mfg.AssemblyEnt Read Committed CS Mfg.BomEnt Read Committed CS Mfg.ComponentEnt Read Committed CS Mfg.LargeOrderEnt Read Committed CS Mfg.PartEnt Read Committed CS Orders.ItemEnt Read Committed CS Supplier.SupplierCompEnt Read Committed CS Supplier.SupplierEnt Read Committed CS The ItemEnt bean was cached for 20 minute intervals by setting is-read-only-bean=true and refresh-period-in-seconds=1200 in the sun-orders.xml deployment descriptor. Only the data inside the bean was cached. Repeatable read beans were accessed using DB2 isolation level RS Read committed beans were accessed using DB2 isolation level CS -------------------------------------------------------------------------------- Durability Requirement Info: To ensure database durability, RAID 1 (mirror disks) was used for the database files and logs on the four Sun StorageTek 3510 arrays. Each application server has a pair of mirrored disks (using Solaris Volume Manager) to provide durability for all the server logs and filestore for JMS persistence. -------------------------------------------------------------------------------- Storage Requirement Info: An 75 minute run at an injection rate of 5100 increased storage by 5707 MB This extrapolates to 100 GB of storage for a 24 hour run. The database is configured with 6132 GB of storage. Each Sun StorageTek 3510 FC Array was configured as a single RAID 1 logical drive. -------------------------------------------------------------------------------- Argument Passing Semantics: Sun Java System Application Server 9.1 uses pass-by-value semantics by default. BILL OF MATERIALS -------------------------------------------------------------------------------- Supplier Description Product No. Qty -------- ---------------------------------------- ------------------ --- Sun SPARC Enterprise T5120, 1.4GHz, 8-core SECAF111Z 6 Sun 8GB Memory Expansion (2x4GB) SESY2C1Z 48 Sun 73GB 10K RPM 2.5" SAS Disk SESY3A11Z 18 Sun DVD, 8X, RW SESY9DV1Z 6 Sun Dual Port GigE UTP Low profile card X7281A-2 6 Sun SE T5120 AC Power Supply SECY9PS11Z 6 Sun Solaris 10 8/07 Preinstalled SESY9SA1Z 6 Sun SunSpectrum Upgrade: 3YGOLD, 24x7 W9D-T5120-8-24-3G 6 Sun Sun Fire E6900 1.95GHz Bundle SYS6900B-4-1950-Z 1 Sun Unibrd: 4 USIV+ @ 1.95 GHz w/16GB US4BRD-448-1950-Z 5 Sun D240 Media Tray 540-4523 1 Sun PCI I/O Assembly SF Midrange Servers X4051A 1 Sun Sun GigaSwift Network Adapter X4150A-2 10 Sun Sun 2GB PCI Dual FC Ntwk Adaptor SG-PCI2FC-QF2-Z 2 Sun Sun Dual GigE + Dual SCSI X4422A-2 2 Sun AC Power Cable Option X3800A 1 Sun SF E6900 O/S Upgrade: 3YGOLD, 24x7 W9D-E69-24-3G 1 Sun SF USIV+ BD OS UPG 3YR GOLD, 24x7 W9D-S4BDPLUS-24-3G 6 Sun Sun StorageTek 3510, 12 x 146GB, 1 RAID XTA3510R01A1R1752Z 3 Sun Sun StorageTek 3510, 12 x 73GB, 1 RAID XTA3510R01A1R876Z 1 Sun SunSpectum Upgrade: 3Y GOLD, 24x7 W9D-SE3510-24-3G 4 Sun Sun Fire X2100 M2 A84-GWZ1-H-512-JL8 1 Sun DVD-ROM Drive X5286A-Z 1 Sun Localized Power Cord X311L 1 Sun 17" Entry Color Monitor X7204A 1 Sun USB Keyboard & Mouse 320-1271 1 Sun SunSpectrum Upgrade: 3YGOLD, 24x7 W9D-A84-24-3G 1 Sun Sun Java System Application Server 9.1 ASE29-00P-B929 6 Each license includes Premium Support for 4 sockets for 1 year IBM DB2 UDB ENTERPRISE SERVER EDITION PROCESSOR D518GLL 48 LIC+SW MAINT 12 MO IBM DB2 UDB ENTERPRISE SERVER EDITION PROCESSOR E00BILL 96 SW MAINT RNWL 1 ANNIV -------------------------------------------------------------------------------- OTHER BENCHMARK INFORMATION -------------------------------------------------------------------------------- The submission used round-robin DNS for load-balance of all network requests. The DNS server was hosted on the database server. This submission used the xerces implementation 2.6.2 provided with Sun Java System Application Server 9.1. -------------------------------------------------------------------------------- General Notes -------------------------------------------------------------------------------- The only errors in the driver log files were those that are normally generated by this benchmark. DB2 uses "Soft" checkpoint to ensure that no updates remain unflushed for longer than the allowed time. When DB2 UDB Server changes a database table with an update, insert, or delete operation, the change is initially made in memory, not on disk. When there is not enough space in the memory buffer to read in or write additional data pages, DB2 UDB Server will make space by flushing some modified pages to disk. Modified pages are also written to disk as part of the "Soft" checkpoint to ensure that no updates remain unflushed for longer than the allowed time. Before a change is made to the database, it is first recorded in the transaction log. This ensures that the database can be recovered completely in the event of a failure. Using the transaction log, transactions that started but did not complete prior to a failure can be undone, and transactions recorded as complete in the transaction log but not yet written to disk can be redone. DB2 UDB uses a write-ahead-logging protocol to guarantee recovery. This protocol uses "Soft" checkpoint to write least-recently-used database to disk independent of transaction commit. However, enough log information to redo/undo the change to a database pages is committed to disk before the database page itself is written. This protocol therefore renders checkpoint unnecessary for DB2 UDB. Network Switch: Cisco Catalyst 4506 10/100/1000 Switch - 48 ports Contains: (1) WS-X4013+, (2) WS-X4424-GB-RJ45 -------------------------------------------------------------------------------- For questions about this result, please contact the submitter: Sun Microsystems Inc. For other inquiries, please contact SPEC - Benchmark run on Sun Oct 21 15:30:54 EDT 2007 by SPECjAppServer2004 v1.08 - Result submitted on Wed Nov 7 03:33:14 EST 2007 - Report generated by SPECjAppServer2004 Reporter v1.03 Copyright (C) 2004 Standard Performance Evaluation Corporation